Ulrich CT Motion Syringeless Contrast Injector

Innovation made in Germany

Ulrich CT Motion Contrast Injector
Ulrich CT Motion Multi Use Contrast Injector
  • Ulrich CT Motion Tandem vs Seamless


- CamHealth - exclusive distributors of the ulrich CT Motion contrast injector for Australian and New Zealand.

 

- The CT motion syringeless power injector is the gold standard in multi-patient power injector technology. Providing advances in hygiene, safety and efficiency.


- Only the patient tubing needs to be changed for each patient – Pump tubing can remain in place in the injector for 24 hours for as many contrast injections as desired.

 

- Patient changeover takes only a few seconds.

​

- Contrast media bottles up to 1L and saline bags are spiked directly onto the system, reducing wastage and increasing contrast efficiency. Seamless switching between 2 contrast media bottles ensures all contrast in the bottle is utilised.

​

- Wireless operation through battery and Bluetooth connectivity

Innovation
ulrich CT Motion Video
Ulrich CT Motion

Ulrich CT Motion

Play Video
Ulrich CT Motion Syringeless Contras Injector

Setup Made Easy

Pump tubing / Day Set can be used for 24 hours - setup once per day

  • Insert 24hr Day Set pump hose

  • Connect patient tubing

  • Attach contrast media bottles and saline bag

         Watch the Setup Video

  • Ulrich CT Motion Setup Video

Patient Changeover in Seconds

  • Detach patient tubing

  • Connect new patient tubing

  • Prime

         Watch the Patient Tubing Change Video

  • Ulrich CT Motion Patient Tubing
Ulrich CT Motion Syringeless Contras Injector
Setup and Patient Change
Ulrich CT Motion Syringeless Contrast Injector

Designed for maximum hygiene and safety

     A closed system is created ensuring maximum levels of hygiene. One way valves ensure a positive flow system.

​

     In-system and patient side air detectors provide protection again against air injections. 

​

     FDA approved and a TGA Certified Device.

​

     Pump day set tubing certified for 24 hour use.

​

     Particle filter and integrated bacterial filters.

Economical and environmental

     Patented technology in combination with two-part tubing system provides a significant saving on consumables cost. The more patients per day, the more economical the injector becomes. 

​

     Savings in contrast media wastage, as all contents of the bottle are utilised.

​

     Reduced volume of wastage - only the patient tubing is disposed of after each patient.

​

     Increased patient throughput and more efficient for staff.

 

     CamHealth's shipping services for consumables are now 100% carbon neutral, at no extra cost

 

Shippit Carbon neutral Logo-RGB-02.png
Ulrich CT Motion Syringeless Contrast Injector Ceiling Mount
Hygiene, Safety, Cost Advantages

Advantages at a Glance

Simple and Stress Free

​

  • Setup once per day

  • Very fast patient changeovers

  • Intuitive operator control concept - very easy to use

  • Wireless operation through battery and Bluetooth connectivity

Economical and Efficient

​

  • Low disposable cost

  • Optimal contrast management - two contrast connections, allowing for high volume contrast bottles

  • Efficient workflow for high patient throughput

  • Reduced wastage volume

Hygienic and Safe

​

  • Closed system

  • Direct injection from original contrast media containers

  • Automatic air monitoring

  • Bacterial filters

  • One-way check valves and positive flow

Advantages at a glance

Applications Training and Installation

​

CamHealth offer industry-leading applications support and training during trials and post-installation. This will ensure your staff are well trained in the day-to-day use of the system and will also gain valuable training on the vast clinical benefits of their ulrich injector.

​

During applications training, the system will be configured with your practice protocols. Applications staff will also be able to work with your staff to adjust protocols where necessary to ensure all the cost and contrast savings, as well as patient safety features of their ulrich Syringeless injector, are taken advantage of.

​

Due to the wireless configuration of the Pedestal version (battery operated injector and bluetoooth connection to the console), installation of the CT Motion is a simple and efficient process, with most sites being fully operational in approximately 30 minutes. 

​

The CT Motion also has a range of reference and training videos for setup and use of the injector, which are accessible on the console by staff at any time. 

​

See more about our Service and Support here.

Applications Training and Instalation
See Beyond RIS PACS Interface.png

ulrich Contrast and Patient Management System

RIS/PACS Interface

The ulrich medical® RIS/PACS interface enables the CT motion contrast media injector from ulrich medical® to be integrated easily and comprehensively into RIS and PACS systems using the DICOM standard.

 

Key Features:

  • Transfer of the DICOM worklist from the RIS using the DICOM Modality Worklist Management SOP-Class

  • Combines patient information from the RIS with contrast injection parameters
  • Intuitive workflow on the CT motion user interface for the easy and fast acquisition of all injection data, e.g. volume, type of contrast media, concentration, expiry date, batch number, eGFR value/date, patient weight and size, cannula size, operator ID as well as the graphic display of flow rate/pressure during the injection time
  • Automatic sending of a comprehensive "CM DOSE REPORT" as a DICOM-SC store to PACS and/or Dose Management systems
  • Reduction of error sources during data acquisition by means of standardised data transfer

​

Contrast and Patient Mangemen System
CT Interface

SYNCopen - Injector interface with CT scanner

​

With the aid of the ulrich medical® SYNCopen interface, data is exchanged between the power injector and the
CT scanner. It is based on the international standard CANopen.

 

Along with the synchronous start/stop of the
devices, injection parameters are transmitted from the power injector to the CT and then on to an RIS/PACS or a dose management software.

​

NOTE:  Functionality is dependant on CT scanner vendor, software version and included accessorie

 

Ulrich CT Motion Syringeless Contrast Injector CT Scanner Integration
CT Motion More Info and Videos